Page 369 - Softbound_Edition_19_de
P. 369
PPrrooppoorrttiioonnaall--SScchhiieebbeerrvveennttiill
LEISTUNGSKENNGRÖSSEN
Ölviskosität u = 30 mm2/s
Q = f (p) Volumenstrom-Druck-Kennlinie Q = f (p) Volumenstrom-Druck-Kennlinie
I = IG I = IG
ACB-S, AC1-S, CB2-S ADB-V
Q [l/min] QN = 32 l/min Q [l/min]
50 K1115 50 K1116
40
40 30
20
30 10 QN = 32 l/min
QN = 16 l/min
QN = 16 l/min 0
0 50 QN = 10 l/min
20 QN = 5 l/min
10 QN = 10 l/min 350 p [bar]
QN = 5 l/min
0 200 250 300 100 150 200 250 300
0 50 100 150 350 p [bar]
∆p = f (Q) Druckverlust-Volumenstrom-Kennlinie ∆p = f (Q) Druckverlust-Volumenstrom-Kennlinie
I = IG I = IG
ACB-S, AC1-S, CB2-S ADB-V
p [bar] QN = 5 l/min QN = 10 l/min QN = 16 l/min p [bar] QN = 5 l/min QN = 10 l/min QN = 16 l/min
QN = 32 l/min QN = 32 l/min
35 K1111 8 12 16 20 35 K1111 8 12 16 20
30 24 28 32 Q [l/min] 30 24 28 32 Q [l/min]
25 25
20 20
15 15
10 10
5 5
0 0
04 04
Q = f (I) Volumenstrom-Verstellverhalten Q = f (I) Volumenstrom-Verstellverhalten
∆p = 10 bar ∆p = 10 bar
ACB-S, AC1-S, CB2-S ADB-V
Q [l/min] Q [l/min]
30 K1113 QN = 32 l/min 30 K1114 QN = 32 l/min
25
25
20 20
15 QN = 16 l/min 15 QN = 16 l/min
10 QN = 10 l/min 10 QN = 10 l/min
5 QN = 5 l/min 5 QN = 5 l/min
0 0
-100 -80 -60 -40 -20 0 20 40 60 80 100 l [%] -100 -80 -60 -40 -20 0 20 40 60 80 100 l [%]
Hinweis! Sämtliche Messungen wurden über zwei Steuerkanten
aufgenommen. Dabei waren die Anschlüsse A und B
kurzgeschlossen.
www.wandfluh.com Abbildung unverbindlich Änderungen vorbehalten 3/5 Ausgabe: 20 23 1.10-77D
Seite 369