Page 413 - Softbound_Edition_19_de
P. 413
Proportional-SchiWebDePrvPeUn1t0il
LEISTUNGSKENNGRÖSSEN
Ölviskosität u = 30 mm2/s
Q = f (p) Volumenstrom-Druck-Kennlinie Q = f (p) Volumenstrom-Druck-Kennlinie
I = IG I = IG
ACB-S ADB-V
Q [l/min] Q [l/min]
30 K4121
30 K4117 25
20
25 15
10
20 P-A P-A
B-T 5 B-T
0
15
0 50
10 P-B P-B
A-T A-T
5
0 100 150 200 250 300 350 p [bar]
0 50 100 150 200 250 300 350 p [bar]
∆p = f (Q Druckverlust-Volumenstrom-Kennlinie
I = IG
p [bar]
20 K4116_1 5 10 15 20 25 Q [l/min]
15
10
5
0
0
Q = f (I) Volumenstrom-Verstellverhalten Q = f (I) Volumenstrom-Verstellverhalten
∆p = 10 bar ∆p = 10 bar
ACB-S ADB-V
Q [l/min] Q [l/min]
20 K4115 20 K4119
16 16
12 P-B P-A 12 P-B P-A
A-T B-T A-T B-T
8 8
4 4
0 0
-100-80 -60 -40 -20 0 20 40 60 80 100 I [%] -100-80 -60 -40 -20 0 20 40 60 80 100 I [%]
QL = f (Q) Leckölvolumenstrom-Kennlinie QL = f (Q) Leckölvolumenstrom-Kennlinie
pro Steuerkante pro Steuerkante
ACB-S ADB-V
Q [cm3/min] Q [cm3/min]
350 K4114 350 K4118_1
300 300
250 250
200 200
150 150
100 100
50 50
0 0
0 50 100 150 200 250 300 350 p [bar] 0 50 100 150 200 250 300 350 p [bar]
Hinweis! Sämtliche Messungen wurden über zwei Steuerkanten
aufgenommen. Dabei waren die Anschlüsse A und B
kurzgeschlossen.
www.wandfluh.com Abbildung unverbindlich Änderungen vorbehalten 3/4 Ausgabe: 19 34 1.10-2720D
Seite 413